Skip to main content

The Alaska Reference Database originated as the standalone Alaska Fire Effects Reference Database, a ProCite reference database maintained by former BLM-Alaska Fire Service Fire Ecologist Randi Jandt. It was expanded under a Joint Fire Science Program grant for the FIREHouse project (The Northwest and Alaska Fire Research Clearinghouse). It is now maintained by the Alaska Fire Science Consortium and FRAMES, and is hosted through the FRAMES Resource Catalog. The database provides a listing of fire research publications relevant to Alaska and a venue for sharing unpublished agency reports and works in progress that are not normally found in the published literature.

Displaying 1 - 25 of 26

Addressing wildfire is not simply a fire management, fire operations, or wildland-urban interface problem - it is a larger, more complex land management and societal issue. The vision for the next century is to: Safely and effectively extinguish fire, when needed; use fire where…
Year: 2011
Type: Document
Source: FRAMES

Hanks
From the text ... 'Risk management is on center stage as an example of the shift in culture for fire and aviation managers.'
Year: 2011
Type: Document
Source: TTRS

Amorim
The validation of the Aerial Drop Model consisted of the comparison of computed ground patterns with experimental data from a set of real-scale drop tests using water and a wide range of fire retardant viscosities. Results were analyzed in terms of pattern length and area. A…
Year: 2011
Type: Document
Source: FRAMES, TTRS

Amorim
The efficiency of the aerial drop of firefighting agents (water and retardants) is extremely dependent on pilot skills in dealing with complex atmospheric conditions, mostly because on-board systems for computer-assisted drops have not yet been used operationally. Hence,…
Year: 2011
Type: Document
Source: FRAMES, TTRS

Parks
From the text ... 'Since the 1950s the US Forest Service (USFS) has relied on fire-retardant chemicals as one method of battling wildland blazes, primarily in the American West. ...In 2004, the Forest Service Employees for Environmental Ethics (FSEEE; Eugene, OR) sued the USFS…
Year: 2011
Type: Document
Source: TTRS

Hawkes
From the text: 'In summary, the coupling of a burning prescription which could deliver adequate fire intensity with gelled gasoline helitorch ignition to overcome some of the fuel arrangement and topographic problems resulted in a generally successful rehabilitation effort at…
Year: 1984
Type: Document
Source: TTRS

Denney
From the text: 'Remember, an aluma-gel mix can 'make or break' a helitorch operation. It is suggested for the inexperienced to invite someone knowledgeable to assist on the heliport and aid in training your mixing crew. Timing is very important. It takes practice for a mixing…
Year: 1984
Type: Document
Source: TTRS

Thomas, Rich
From the Summary: 'Helitorch burning is a complex system of organization consisting of three subsystems: (1) HELITORCH ON THE GROUND, (2) HELITORCH OVER BURNING BLOCK, and (3) MANAGEMENT OF HELITORCH BEFORE ARRIVAL AT BURN SITE AND AFTER IGNITION. In each subsystem events have…
Year: 1984
Type: Document
Source: TTRS

Lait
Text: 'Fire suppression offers the fire manager little or no time to prepare personnel for tasks which require considerable logistical preparation. Usually these aspects such as air tanker loading and retardant mixing are contracted out and are very expensive. Techniques such as…
Year: 1984
Type: Document
Source: TTRS

McCleese
From the text: 'As the use of prescribed fire grows, the demand for more efficient and effective methods of ignition will grow with it. Once the opportunities for fire use are recognized, program managers will have to seek more effective ways to keep up with the increasing…
Year: 1984
Type: Document
Source: TTRS

Bentley
Command and control of Champion's helitorch operations have so far amounted to the ignition boss being located on the ground. The alternative forms of command and control, which include ignition boss in chase helicopter or ignition boss in ignition helicopter, have not been used…
Year: 1984
Type: Document
Source: TTRS

Palmer
From the text: 'These increases in feelings of accomplishments or job security do not, however, come without a price. What is the price? Increased exposure to accidents, loss of lives or injury to your personnel, and increased workload to name a few.'
Year: 1984
Type: Document
Source: TTRS

Kendrick
From the text: 'The pilot on any aerial ignition operation is presented with an extremely difficult task. It has been CDF's experience that having a trained helitack captain on board, acting as the lighting supervisor, reduces significantly the burdon on the pilot, while adding…
Year: 1984
Type: Document
Source: TTRS

Bohannan
From the text: 'Helitorch, waterbucket, and long-line flying offer some of the most difficult and hazardous flying one can do with a helicopter. The FAA, Part 133, allows for only 'essential crew members' to be on board during external load operations. An Ignition Boss/Fire Boss…
Year: 1984
Type: Document
Source: TTRS

Lasko
From the text: 'In summary, a number of command and control alternatives are available for use with aerial ignition systems. Due to the variety of situations encountered in the field, the burn boss must select the alternative that matches the situation and will provide for a…
Year: 1984
Type: Document
Source: TTRS

Bunnell
From the Summary: 'There are several reasons to use helitorch ignition instead of hand ignition. Three primary reasons are safety of ground ignition personnel, cost effectiveness, and ability to meet resource objectives.'
Year: 1984
Type: Document
Source: TTRS

Lafferty
From the Introduction: 'In British Columbia several aerial ignition systems are used: the gas/diesel/JP-4 drip torch, the gelled gasoline helitorch, and the aerial ignition device (AID). This paper deals mainly with the experiences of MacMillan Bloedel Ltd. (MB) and Forest…
Year: 1984
Type: Document
Source: TTRS

Hunter
From the Conclusions ... 'The coordination of the helitorch operations, such as support services, unit ignition procedures, and timing, is of a critical nature. It is imperative that a smooth flow of effort be immediately established and maintained throughout a burn. Oversights…
Year: 1984
Type: Document
Source: TTRS

Lionberger
From the Introduction: 'Aerial ignition, as a part of prescribed fire and wildfire management, is rapidly growing in popularity. Since the early 1970's when development began, many improvements have been made by both the private sector and government agencies. The 'flying drip…
Year: 1984
Type: Document
Source: TTRS

Wakimoto
The magnitude of prescribed fire use has greatly increased in the past 10 years. With this expanded use of fire came a need for aerial ignition devices and techniques. This paper reports the preliminary findings of a nationwide survey of active aerial ignition prfactitioners.…
Year: 1984
Type: Document
Source: TTRS

Brown
From the Final Remarks...'Designing fire prescriptions to meet today's demand for skill and professionalism requires an orderly planning process. At the start of this process, fire objectives must be derived from land managment objectives and specifically stated in terms of what…
Year: 1984
Type: Document
Source: TTRS

Heilman
From the Introduction ... ' As prescribed fire became more widely understood and applied in the U.S. in the decades following World War II, forest managers routinely used aircraft for various purposes in prescribed fire operations. In the U.S., this most often was the helicopter…
Year: 1984
Type: Document
Source: TTRS

González-Cabán
Wildfires are a significant social problem affecting millions of people worldwide and causing major economic impacts at all levels. In the US, the severe fires of 1910 in Idaho and Montana galvanized a fire policy excluding fire from the ecosystem by the U.S.Department of…
Year: 2011
Type: Document
Source: FRAMES

Calkin, Phipps, Holmes, Rieck, Thompson
A cornerstone of effective institutional learning and accountability is the development, tracking, and analysis of informative performance measures. In a previous issue of Fire Management Today ('A New Look at Risk Management,' Winter 2011), a series of articles highlighted the…
Year: 2011
Type: Document
Source: FRAMES

Rothermel
Aerial ignition devices are being used which can start fires by a succession of point sources or by a line of fire. Through the use of these devices, the fire manager has considerable control of the fire situation. Control of the ultimate fire behavior depends on the ignition…
Year: 1984
Type: Document
Source: FRAMES, TTRS